Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Gen Dent ; 71(5): 53-57, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37595084

RESUMO

Determining the appropriate technique for diastema closure is challenging, and the decision must be evidence based. The objective of these case reports is to describe different approaches to diastema closure using direct and indirect techniques, focusing on the characteristics of the patient and clinical requirements to guide treatment. In the first case, a 16-year-old patient had multiple diastemas in the maxillary anterior dentition. The clinical evaluation revealed microdontia of the lateral incisors and malpositioned teeth. The treatment included tooth whitening and placement of composite resin veneers using a direct technique. In the second case, a 54-year-old patient displayed a disharmonious and esthetically compromised smile due to small teeth, color changes, multiple diastemas, incisal wear, and severe dentogingival disproportion. Based on the patient's expectations, the patient's age, and the presence of a "black triangle" interdental space, a multidisciplinary restorative treatment was proposed, including gingivoplasty, tooth whitening, and placement of ceramic laminate veneers using an indirect technique. Both approaches achieved successful esthetic rehabilitation and diastema closure with minimal intervention. The choice of procedure and restorative material, as well as the need for tooth preparation, varied based on the clinical requirements, patient expectations, and financial constraints. Careful treatment planning avoided lengthy and inefficient procedures.


Assuntos
Diastema , Má Oclusão , Humanos , Adolescente , Pessoa de Meia-Idade , Diastema/terapia , Estética Dentária , Facetas Dentárias , Cerâmica , Resinas Compostas/uso terapêutico
2.
J Esthet Restor Dent ; 35(3): 442-448, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36161755

RESUMO

OBJECTIVE: This case report described the use of a stamping technique associated with a bulk fill composite to restore an ICDAS 4 carious lesion on a posterior tooth. The 4-year follow-up is also presented. CLINICAL CONSIDERATIONS: A 32-year-old patient presented a carious lesion on tooth 36 with an underlying dark shadow at the dentin seen from the noncavitated enamel occlusal surface, which was compatible with an ICDAS 4 carious lesion. The lesion was radiographically detected and the caries disease was treated with dietary and hygiene habits orientations. Before accessing the lesion and selectively removing the carious tissue, an occlusal stamp was made by applying a flowable resin composite to copy the anatomy of the noncavitated enamel surface. The cavity was restored using a bulk fill resin composite (Opus Bulk Fill, FGM) with 4-mm-thick increments. Before curing the last increment, a Teflon band was adapted at the uncured bulk fill composite surface and the occlusal stamp made with the flowable composite was pressed against it to reproduce the natural characteristics and initial occlusal anatomy. The top surface was light-activated for 40 s. After 4 years, small wear could be seen in the restoration, but still within clinically acceptable levels. CONCLUSION: The occlusal stamp technique allows reproduction of the natural anatomy of teeth affected by ICDAS 4 carious lesions with good clinical longevity over 4 years. CLINICAL SIGNIFICANCE: This case report presents the use of the stamp technique to restore a tooth affected by an ICDAS 4 lesion, in which a carious process reached the dentin and the enamel anatomy was still preserved. The bulk fill resin composite associated with the occlusal stamp was chosen to quickly restore the cavity with clinical predictability. Bulk fill composites allow the insertion of up to 4-mm-thick increments and offer lower shrinkage stress, good clinical longevity and a less time-consuming procedure in cases of posterior teeth, especially if associated with the stamp technique.


Assuntos
Cárie Dentária , Humanos , Adulto , Seguimentos , Cárie Dentária/terapia , Esmalte Dentário , Resinas Compostas , Restauração Dentária Permanente
3.
Artigo em Inglês | MEDLINE | ID: mdl-35353092

RESUMO

Teeth affected by molar incisor hypomineralization (MIH) present micromorphologic changes and hypersensitivity, which increase the risk of developing caries lesions and affect bonding procedures. Considering that practitioners still misdiagnose teeth affected by MIH, there is an urge for more knowledge about this topic in order to propose a more adequate and conservative treatment. The purpose of this study was to report the clinical challenges regarding the restorative management of a patient with MIH. A 13-year-old girl sought dental treatment, complaining about hypersensitivity in posterior teeth. Under clinical exams, notable enamel alterations mainly affecting posterior teeth (including molars) presented particular characteristics frequently attributed to MIH, and visible stains on maxillary central incisors were present. Because the mineral and organic content of MIH-affected enamel differ from sound enamel, it may imply special care for bonding of a restorative material. Thus, in order to promote a minimally invasive approach, selective removal of carious tissue and restoration with microhybrid composite resin was conducted after application of a universal bonding system used as self-etching strategy. After a 2-year follow-up, the restorations presented good clinical performance and the patient had limited hypersensitivity discomfort, suggesting a promising performance.


Assuntos
Hipoplasia do Esmalte Dentário , Restauração Dentária Permanente , Adolescente , Esmalte Dentário , Restauração Dentária Permanente/métodos , Feminino , Humanos , Incisivo/patologia , Dente Molar
4.
Dent Mater J ; 40(1): 150-156, 2021 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-32999257

RESUMO

This study aimed to analyze the interaction of a MDP-based universal dentin bonding system (DBS) with Er, Cr: YSGG laser irradiation, measuring the microtensile bond strength to dentin over a six-month period. The experimental design involved three factors: DBS (Adper Scotchbond Universal; Clearfil SE Bond, Adper Scotchbond Multipurpose and Adper Single Bond 2), laser (Control and Er, Cr: YSGG), and time (initial- 7 days and 6 months). Eighty dentin samples from molars were prepared (n=10) with laser irradiation after primer and DBS application. After 7 days, were subjected to micro tensile bond strength test. The data were analyzed by three-way ANOVA and Tukey tests (p<0.05). Both DBS and laser significantly affected the bonding performance and their interaction was statistically significant (p=0.0194). The self-etching mode of the MDP-based universal DBS maintained the bond strength on dentin irradiated with ER, Cr: YSGG after 6 months, while bonding with all other DBS deteriorated.


Assuntos
Colagem Dentária , Lasers de Estado Sólido , Dentina , Adesivos Dentinários , Cimentos de Resina , Resistência à Tração
5.
Dent Mater J ; 38(3): 403-410, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30918231

RESUMO

The present in vitro study assessed the polymerization shrinkage/PS, Knoop microhardness/KHN and depth of cure/DC of 9 different resin composites : Filtek Bulk Fill Flowable (FBF), Surefill SDR flow (SDR), Xtra Base (XB), Filtek Z350XT Flowable (Z3F), Filtek Bulk Fill Posterior (FBP), Xtra Fill (SF), Tetric Evo Ceram Bulk Fill (TBF), Admira Fusion Xtra (ADM), and Filtek Z350XT (Z3XT). PS was assessed with a µ-CT machine, scanning 64 mm3 samples (n=8) before and after 20 s curing. KHN and DC were performed with a microhardness tester (n=8 for each group) right after 20 s light curing, with 3 readings per depth at every 0.5 mm. Low viscosity resin composites showed lower KHN values when compared with high viscosity resins. Z3XT showed the highest microhardness among the tested resin composites. Z3XT and Z3F showed lower DC when compared with bulk fill resin composites. All bulk fill resin composites presented depth of cure higher than 4.5 mm and similar or lower PS than conventional resin composites.


Assuntos
Resinas Compostas , Teste de Materiais , Polimerização , Propriedades de Superfície , Viscosidade
6.
J Appl Oral Sci ; 27: e20180132, 2019 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-30624465

RESUMO

Bulk-fill composites were introduced in dentistry to accelerate clinical procedures while providing adequate outcomes. Concerns regarding the use of bigger composite increments rely on the polymerization shrinkage and shrinkage stress, which may generate gaps on the adhesive interface and result in a reduced success rate. OBJECTIVE: To evaluate the polymerization shrinkage stress of different bulk-fill resin composites and their elastic modulus. MATERIALS AND METHODS: Fourteen specimens were made for each of the nine different resin composites (seven with 12 mm3 and seven with 24 mm3): Surefill SDR flow (SDR), X-tra Base (XB), Filtek Bulk Fill Flowable (FBF), Filtek Z350XT Flow (Z3F); Tetric Evo Ceram Bulk Fill (TBF), X-tra Fil (XF), Filtek Bulk Fill (FBP), Admira Xtra Fusion (ADM) and Filtek Z350 XT (Z3XT). Linear shrinkage stress was evaluated for 300 s with the aid of a linear shrinkage device adapted to a Universal Testing Machine. For each composite group, seven additional specimens (2x2x25 mm) were made and Young's modulus was evaluated with a 3-point bending device adapted in a Universal Testing Machine with 0.5 mm/min crosshead speed and 50 KgF loading cell. RESULTS: For 12 mm3 specimens, three-way ANOVA showed that only SDR and TBF generated lower stress after 20 s. Considering 300 s, TBF, SDR, and XF generated the lowest stress, followed by ADM, FBP, XB, and FBF, which were similar to Z3XT. Z3F generated the highest stress values for all time points. Considering 24 mm3 specimens after 20 s, all bulk fill composites generated lower stress than Z3XT, except XB. After 300 s, SDR, FBP, and ADM generated the lowest stress, followed by TBF and XF. For elastic modulus, one-way ANOVA showed that FBF, SDR, Z3F, and ADM presented the lowest values, followed by XB and TBF. FBP, Z3XT, and XF presented the highest elastic modulus among the evaluated composites. CONCLUSIONS: Bulk-fill resin composites presented equal to lower shrinkage stress generation when compared to conventional composites, especially when bigger increments were evaluated. Bulk-fill composites showed a wide range of elastic modulus values, but usually similar to "regular" composites.


Assuntos
Resinas Compostas/química , Módulo de Elasticidade , Polimerização , Estresse Mecânico , Análise de Variância , Análise do Estresse Dentário , Teste de Materiais , Metacrilatos/química , Valores de Referência , Reprodutibilidade dos Testes , Siloxanas/química , Estatísticas não Paramétricas , Propriedades de Superfície
7.
Gen Dent ; 67(1): 47-50, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30644831

RESUMO

Zirconia-reinforced lithium silicate (ZLS) has recently been introduced in an effort to improve the mechanical properties of glass-ceramic materials. In vitro evaluations suggest that this class of material has high flexural strength and exhibits satisfactory adhesion to resin cement and wear resistance. Since few clinical reports of this novel material are currently available, the aim of this case report is to describe clinical perceptions regarding the handling and performance of ZLS ceramics when used for laminate veneers on the maxillary incisors.


Assuntos
Cerâmica/química , Porcelana Dentária , Lítio , Silicatos/química , Zircônio/química , Colagem Dentária/métodos , Seguimentos , Humanos , Lítio/química , Teste de Materiais , Propriedades de Superfície
8.
J Appl Oral Sci ; 27: e20180126, 2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30540073

RESUMO

OBJECTIVES: The aim of this in vitro study was to evaluate the bonding strength of non-simplified dentin bonding systems (DBS) to dentin irradiated with a diode laser (970 nm) immediately and after 12 months of water storage following either primer or bond application. MATERIAL AND METHODS: The experimental design included three different factors: DBS type [AdperTM Scotchbond Multipurpose (MP) and Clearfil™ SE Bond (CSE)], irradiation [without irradiation - control (C), irradiation after primer application (AP), and irradiation after bond application (AB)], and time [initial (I) and after 12 months of water storage (12 m)]. Sixty sound human third molars (n = 10) were obtained, and their flat occlusal dentin areas were prepared and standardized. Laser irradiation was performed in the contact mode perpendicular to the dental surface over an automatically selected scanning area at a pulse energy of 0.8 W, frequency of 10 Hz, and energy density of 66.67 J/cm2. After 7 days of treatment, the specimens were cut, and half of them were subjected to microtensile testing (500 N/0.05 mm/min), whereas the remaining sticks were examined after 12 months of water storage. The obtained data were analyzed by three-way analysis of variance (ANOVA) followed by a Tukey test (p<0.05). The observed fracture modes were investigated using a portable digital microscope with a magnification of 40x. RESULTS: Among the utilized DBS, MP generally exhibited higher bond strengths, but did not always differ from CSE under similar conditions. The irradiation factor was statistically significant only for the MP/AB groups. After 12 months of storage, all groups demonstrated a significant reduction in the bond strength, whereas the results of fracture analysis showed a predominance of the adhesive type. CONCLUSIONS: The laser treatment of non-simplified DBS was not able to stabilize their bonding characteristics after 12 months.


Assuntos
Colagem Dentária/métodos , Adesivos Dentinários/efeitos da radiação , Dentina/efeitos da radiação , Lasers Semicondutores , Cimentos de Resina/efeitos da radiação , Análise de Variância , Dentina/efeitos dos fármacos , Adesivos Dentinários/química , Humanos , Teste de Materiais , Microscopia de Força Atômica , Polimerização/efeitos da radiação , Valores de Referência , Reprodutibilidade dos Testes , Cimentos de Resina/química , Propriedades de Superfície/efeitos da radiação , Resistência à Tração , Fatores de Tempo , Água/química
9.
Photodiagnosis Photodyn Ther ; 24: 22-26, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30118904

RESUMO

BACKGROUND: The use of hybrid-light (HL) during in-office teeth bleaching can provide faster and reliable results after a single bleaching session, especially if associated with previous acid etching. The present in vivo, interventional, split-mouth, triple-blinded and randomized study evaluated the efficiency of a HL, with and without prior enamel acid etching, assessing the gel application time, degree of color change, sensitivity and treatment stability up to 12 months. METHODS: Thirty-four patients were selected and randomly divided into four groups. The color was evaluated using a spectrophotometer with the CIELab color system, and a VAS questionnaire was used to evaluate the sensitivity. Both upper and lower hemiarches (GI and III) received enamel acid etching with 37% phosphoric acid for 15 s prior to the application of 35% hydrogen peroxide gel (HP). For GI and II, HP was applied on both dental arches for 3-4 consecutive applications and activated by HL (2 × 3' activations with 1' interval); and 3 × 15' (HP) for GIII and IV without HL. Patients returned in 24 h, 1 week, 1-, 6- and 12-months intervals. The clinical operator was different from the clinical measurements operator. RESULTS: After 3-way ANOVA, Tukey's, Wilcoxon and Mann-Whitney tests, all with p < 0.05, no statistical differences were observed between the groups regarding color change (ΔE) and sensitivity in all evaluations. The lowest gel application time was observed for GII (acid etch + HL), followed by GI (HL). CONCLUSIONS: The present study's results reveal the advantages of HL associated with acid etching prior to in office bleaching.


Assuntos
Condicionamento Ácido do Dente/métodos , Peróxido de Hidrogênio/uso terapêutico , Ácidos Fosfóricos/uso terapêutico , Fotoquimioterapia/métodos , Clareadores Dentários/uso terapêutico , Clareamento Dental/métodos , Adolescente , Adulto , Terapia Combinada , Técnicas Cosméticas , Esmalte Dentário/efeitos dos fármacos , Sensibilidade da Dentina , Humanos , Fatores de Tempo , Adulto Jovem
10.
J Mech Behav Biomed Mater ; 85: 170-174, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29902777

RESUMO

The purpose of this in vitro study was to compare the micro hardness, color stability/ΔE, and degree of conversion/DC of a resin cement light cured through different ceramic spacers. Lithium-disilicate ceramic samples were obtained from IPS E-max CAD blocks (HT A1) and IPS in-Ceram (transparent neutral); and divided in 7 groups (n = 8 for each test): CTR/control group; 06 M/0.6 mm monolithic; 12 M/1.2 mm monolithic; 20 M/2.0 mm monolithic; 06B/0.4 + 0.2 mm bilayered; 12B/1.0 + 0.2 mm bilayered; 20B/1.8 + 0.2 mm bilayered. The resin cement (Variolink veneer) was light cured through the ceramic spacers. The resin cement samples were evaluated for ΔE using a spectrophotometer after 24 h, 7days and after aging (24 h in water at 60 °C). Knoop microhardness and DC tests were conducted immediately after light curing, after 24 h and 7days. All experimental groups showed similar microhardness values, although being lower than CTR group. Similar results were observed after 7days. ΔE was similar between all groups after 24 h (except for 12B and 20B), and increased for all groups after 7days and after artificial aging, especially for thicker and bilayer groups. Only 06 M showed values similar to CTR group. DC values were similar to all groups immediately after light curing, increasing after 24 h and 7days. After 7days, only group 20B showed lower DC than CTR group. A tendency of higher DC could be observed for monolithic and thinner ceramics. All test results showed strong correlation (0.9987). Ceramic interposition can reduce mechanical and physical properties of resin cements, especially with thicker and bilayered ceramics. Group 06 M showed the best ΔE overtime.


Assuntos
Cerâmica/química , Luz , Fenômenos Mecânicos , Cimentos de Resina/química , Porcelana Dentária/química , Fatores de Tempo
11.
J Prosthodont ; 27(5): 449-455, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27455118

RESUMO

PURPOSE: To evaluate the color change caused by post-irradiation conversion (ΔE24h and ΔE8 days ) and artificial aging (ΔEAGING ) of resin cements light activated through ceramics of different opacities immediately and 6 minutes after manipulating the material. MATERIALS AND METHODS: Resin cement disks (Allcem and LuxaCore) were light activated through ceramics (without ceramic, e.max HT, LT, and MO) immediately and 6 minutes after the manipulation (n = 10). Spectrophotometry was used to evaluate ΔE24h and ΔE8 days after 37˚C-dry-dark-storage for 24 hours and 8 days, and ΔEAGING after 60˚C-water-storage for 24 hours. Data were analyzed with three-way ANOVA and Tukey's HSD (α = 0.05). RESULTS: Regarding the post-irradiation color change, significant differences were found between the cements (p < 0.0001), light activation protocols (p = 0.037), and ceramics (p < 0.001). The immediate activation (16.2 ± 0.1) showed lower ΔE values than the delayed activation (16.5 ± 0.1). Ceramics influenced the ΔE values as follows: MO (14.0 ± 1.2) < LT (14.9 ± 1.2) ≈ HT (15.4 ± 1.2) < control (21.2 ± 1.2). Regarding ΔEAGING , significant differences were found between cements (p < 0.001), light activation (p = 0.006), and ceramics (p < 0.001). The delayed activation (8.4 ± 0.1) showed lower values than the immediate activation (8.9 ± 0.1). Ceramic spacers influenced ΔEAGING as follows: control (5.6 ± 0.2) < MO (6.6 ± 0.2) < HT (11.0 ± 0.2) ≈ LT (11.5 ± 0.2). CONCLUSION: The delayed light activation resulted in increased color stability, while the ceramic interposition resulted in lower color stability.


Assuntos
Cor , Cura Luminosa de Adesivos Dentários , Cimentos de Resina/efeitos da radiação , Óxido de Alumínio , Resinas Compostas , Porcelana Dentária , Teste de Materiais , Espectrofotometria , Propriedades de Superfície
12.
Gen Dent ; 65(6): e13-e16, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29099376

RESUMO

Due to improvements in esthetic dentistry, the number of patients seeking to obtain a more harmonious smile has increased. A 40-year-old woman was referred for treatment because she was dissatisfied with the effect that diastemas and a conoid tooth had on her smile. Her maxillary anterior teeth were relatively short, resulting in a compromised esthetic relationship between height and width. Orthodontic treatment for better distribution of her teeth was recommended to the patient, but she refused, wanting faster and less expensive treatment. After diagnostic and waxed-up study casts were obtained, composite resin esthetic mock-ups were made to confirm that sufficient space was left for formation of the interdental papilla. After the patient approved the mock-ups, her anterior teeth were submitted to bleaching, definitive restoration, and additional occlusal adjustments. At the 1-year follow-up, the patient exhibited a harmonious, esthetic smile without black spaces or periodontal inflammation.


Assuntos
Papila Dentária , Restauração Dentária Permanente , Diastema/terapia , Estética Dentária , Anormalidades Dentárias/terapia , Adulto , Resinas Compostas , Feminino , Humanos , Sorriso , Clareamento Dental
13.
J Appl Oral Sci ; 25(4): 381-386, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28877276

RESUMO

OBJECTIVE: This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. MATERIAL AND METHODS: Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). RESULTS: Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (µg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. CONCLUSION: Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Assuntos
Adesivos Dentinários/efeitos da radiação , Lasers Semicondutores , Polimerização/efeitos da radiação , Luzes de Cura Dentária , Cimentos Dentários/química , Cimentos Dentários/efeitos da radiação , Adesivos Dentinários/química , Cura Luminosa de Adesivos Dentários/métodos , Transição de Fase/efeitos da radiação , Processos Fotoquímicos/efeitos da radiação , Valores de Referência , Reprodutibilidade dos Testes , Solubilidade/efeitos da radiação , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos da radiação
14.
J. appl. oral sci ; 25(4): 381-386, July-Aug. 2017. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893641

RESUMO

Abstract Simplified dentin-bonding systems are clinically employed for most adhesive procedures, and they are prone to hydrolytic degradation. Objective This study aimed to investigate the effect of laser diode irradiation on the degree of conversion (DC), water sorption (WS), and water solubility (WSB) of these bonding systems in an attempt to improve their physico-mechanical resistance. Material and Methods Two bonding agents were tested: a two-step total-etch system [Adper™ Single Bond 2, 3M ESPE (SB)] and a universal system [Adper™ Single Bond Universal, 3M ESPE (SU)]. Square-shaped specimens were prepared and assigned into 4 groups (n=5): SB and SU (control groups - no laser irradiation) and SB-L and SU-L [SB and SU laser (L) - irradiated groups]. DC was assessed using Fourier transform infrared spectroscopy with attenuated total reflectance. Additional uncured resin samples (≈3.0 µL, n=5) of each adhesive were also scanned for final DC calculation. For WS/WSB tests, similar specimens (n=10) were prepared and measured by monitoring the mass changes after dehydration/water storage cycles. For both tests, adhesive fluids were dropped into standardized Teflon molds (6.0×6.0×1.0 mm), irradiated with a 970-nm laser diode, and then polymerized with an LED-curing unit (1 W/cm2). Results Laser irradiation immediately before photopolymerization increased the DC (%) of the tested adhesives: SB-L>SB>SU-L>SU. For WS/WSB (μg/mm3), only the dentin bonding system (DBS) was a significant factor (p<0.05): SB>SU. Conclusion Irradiation with a laser diode improved the degree of conversion of all tested simplified dentin bonding systems, with no impact on water sorption and solubility.


Assuntos
Adesivos Dentinários/efeitos da radiação , Lasers Semicondutores , Polimerização/efeitos da radiação , Valores de Referência , Solubilidade/efeitos da radiação , Propriedades de Superfície/efeitos da radiação , Reprodutibilidade dos Testes , Adesivos Dentinários/química , Espectroscopia de Infravermelho com Transformada de Fourier , Estatísticas não Paramétricas , Cimentos Dentários/efeitos da radiação , Cimentos Dentários/química , Transição de Fase/efeitos da radiação , Cura Luminosa de Adesivos Dentários/métodos , Luzes de Cura Dentária , Processos Fotoquímicos/efeitos da radiação
15.
Compend Contin Educ Dent ; 38(3): 144-149; quiz 150, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28257221

RESUMO

Often, young patients (≤30 years old) present with carious lesions that progress acutely, compromising a large amount of tooth structure. In these cases, a treatment to prevent the occurrence of pulp exposure and promote remineralization of caries-affected dentin is necessary to maintain healthy dental structure and allow more conservative interventions. The approach will be different when pulp exposure occurs: The therapeutic treatments will be focused on reparative dentin formation and prevention of microorganisms penetrating the pulp organ. Due to the different possible treatments that can be performed to avoid pulp necrosis and the various materials that can be used for this purpose, professionals may have some difficulties understanding all the indications for conservative pulp treatments. The objective of this article is to describe and discuss a successful pulp capping and stepwise excavation associated with restorative treatment for deep caries lesions of anterior upper teeth.


Assuntos
Cárie Dentária/terapia , Capeamento da Polpa Dentária , Necrose da Polpa Dentária/prevenção & controle , Restauração Dentária Permanente/métodos , Criança , Preparo da Cavidade Dentária , Humanos , Masculino , Remineralização Dentária
16.
Full dent. sci ; 8(32): 63-68, 2017. ilus
Artigo em Inglês | BBO - Odontologia | ID: biblio-916225

RESUMO

Tooth wear associated with bone loss, gingival recessions and root exposure of the anterior teeth determine the characteristics of an aged smile. The present clinical case reports the aesthetic treatment of a middle-aged patient who had a prematurely aged smile. After anamnesis and physical examination, it was found that episodes of bone loss had occurred, however, previous periodontal treatment had satisfactorily controlled the disease. And yet it was also observed wear of the upper anterior teeth and fracture on tooth 11. Treatment plan included the confection of direct veneers with composite resin, without the need for tooth structure wear. At the end of the first session, it was observed that although an aesthetic result was already achieved, the ratio of height and width of the incisors had not yet been standardized. Thus, orthodontic rubbers were used for three days for tooth movement and increase of mesiodistal dimension of the central and lateral incisors. The present case demonstrates excellent aesthetic results and patient satisfaction. It was concluded that in the current case report it was possible to satisfactorily rejuvenate smile with direct application of composite resin (AU).


O desgaste dentário associado à perda óssea, recessão gengival e exposição radicular dos dentes anteriores determinam características de um sorriso envelhecido. O presente caso clínico relata o tratamento estético de uma paciente de meia idade, que apresentava sorriso precocemente envelhecido. Após anamnese e exame físico, constatou-se que episódios de perda óssea ocorreram, no entanto, o tratamento periodontal prévio já havia controlado a doença de forma satisfatória. Observou-se ainda desgaste dos dentes anteriores superiores e fratura no elemento ente 11. O plano de tratamento incluiu a realização de facetas diretas de resina composta, sem a necessidade de desgaste da estrutura dentária. Ao final da primeira sessão, observou-se que, apesar de um resultado estético já obtido, a proporção de altura e largura dos incisivos não havia ainda sido normalizada. Assim, borrachas ortodônticas foram utilizadas por três dias para movimentação dos dentes e aumento da dimensão mésio-distal dos incisivos centrais e laterais. Este caso mostra excelentes resultados estéticos e satisfação do paciente. Concluiu-se que, no presente caso clínico, foi possível rejuvenescer o sorriso de forma satisfatória com aplicação de resinas compostas diretas (AU).


Assuntos
Humanos , Feminino , Pessoa de Meia-Idade , Sorriso , Resinas Compostas , Facetas Dentárias , Estética Dentária , Desgaste dos Dentes , Brasil
17.
J Appl Oral Sci ; 24(2): 136-41, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27119761

RESUMO

The use of light sources in the bleaching process reduces the time required and promotes satisfactory results. However, these light sources can cause an increase in the pulp temperature. Objective The purpose of the present study was to measure the increase in intrapulpal temperature induced by different light-activated bleaching procedures with and without the use of a bleaching gel. Material and Methods A human maxillary central incisor was sectioned 2 mm below the cementoenamel junction. A K-type thermocouple probe was introduced into the pulp chamber. A 35% hydrogen peroxide bleaching gel was applied to the vestibular tooth surface. The light units used were a conventional halogen, a hybrid light (only LED and LED/Laser), a high intensity LED, and a green LED light. Temperature increase values were compared by two-way ANOVA and Tukey´s tests (p<0.05). Results There were statistically significant differences in temperature increases between the different light sources used and between the same light sources with and without the use of a bleaching gel. The presence of a bleaching gel generated an increase in intra-pulpal temperature in groups activated with halogen light, hybrid light, and high intensity LED. Compared to the other light sources, the conventional halogen lamp applied over the bleaching gel induced a significant increase in temperature (3.83±0.41°C). The green LED unit with and without gel application did not produce any significant intrapulpal temperature variations. Conclusion In the present study, the conventional halogen lamp caused the highest increase in intrapulpal temperature, and the green LED caused the least. There was an increase in temperature with all lights tested and the maximum temperature remained below the critical level (5.5°C). The addition of a bleaching gel led to a higher increase in intrapulpal temperatures.


Assuntos
Polpa Dentária/efeitos da radiação , Temperatura Alta , Lasers Semicondutores , Luz , Clareamento Dental/métodos , Análise de Variância , Polpa Dentária/efeitos dos fármacos , Géis , Humanos , Peróxido de Hidrogênio/efeitos da radiação , Oxidantes/efeitos da radiação , Valores de Referência , Reprodutibilidade dos Testes , Clareamento Dental/instrumentação
18.
J. appl. oral sci ; 24(2): 136-141, Mar.-Apr. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-779900

RESUMO

ABSTRACT The use of light sources in the bleaching process reduces the time required and promotes satisfactory results. However, these light sources can cause an increase in the pulp temperature. Objective The purpose of the present study was to measure the increase in intrapulpal temperature induced by different light-activated bleaching procedures with and without the use of a bleaching gel. Material and Methods A human maxillary central incisor was sectioned 2 mm below the cementoenamel junction. A K-type thermocouple probe was introduced into the pulp chamber. A 35% hydrogen peroxide bleaching gel was applied to the vestibular tooth surface. The light units used were a conventional halogen, a hybrid light (only LED and LED/Laser), a high intensity LED, and a green LED light. Temperature increase values were compared by two-way ANOVA and Tukey´s tests (p<0.05). Results There were statistically significant differences in temperature increases between the different light sources used and between the same light sources with and without the use of a bleaching gel. The presence of a bleaching gel generated an increase in intra-pulpal temperature in groups activated with halogen light, hybrid light, and high intensity LED. Compared to the other light sources, the conventional halogen lamp applied over the bleaching gel induced a significant increase in temperature (3.83±0.41°C). The green LED unit with and without gel application did not produce any significant intrapulpal temperature variations. Conclusion In the present study, the conventional halogen lamp caused the highest increase in intrapulpal temperature, and the green LED caused the least. There was an increase in temperature with all lights tested and the maximum temperature remained below the critical level (5.5°C). The addition of a bleaching gel led to a higher increase in intrapulpal temperatures.


Assuntos
Humanos , Polpa Dentária/efeitos da radiação , Lasers Semicondutores , Luz , Clareamento Dental/métodos , Análise de Variância , Polpa Dentária/efeitos dos fármacos , Géis , Temperatura Alta , Peróxido de Hidrogênio/efeitos da radiação , Oxidantes/efeitos da radiação , Valores de Referência , Reprodutibilidade dos Testes , Clareamento Dental/instrumentação
19.
Full dent. sci ; 7(26): 114-118, abr. 2016. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-786855

RESUMO

A pigmentação melânica gengival é uma condição clínica mais prevalente em indivíduos da raça negra e oriental, consistindo frequentemente em um problema estético. Embora a recidiva seja imprevisível, vários tratamentos são propostos, entre eles a mucodermoabrasão com diferentes instrumentos. O objetivo do presente relato de caso clínico foi demonstrar duas técnicas para resolução desses casos: emprego dos gengivótomos e de uma ponta de cerâmica em alta rotação.


Gingival melanin pigmentation is a clinical condition, more prevalent in oriental and black people, and may generate esthetical problems. Despite the fact that recurrence is unpredictable, different treatments are proposed, such as epithelial abrasion with different instruments. The objective of the present case report is to show two different techniques for resolution of such cases: use of Kirkland periodontal knife, and abrasive ceramic burs in high speed.


Assuntos
Humanos , Gengiva , Melaninas , Pigmentação , Procedimentos Cirúrgicos Operatórios/métodos
20.
Gen Dent ; 64(2): 33-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26943086

RESUMO

The aim of this in vitro study was to evaluate the loss of tooth structure after cavity preparation for direct (retentive) and indirect (nonretentive) restorations and its relationship to the fracture strength of the prepared tooth. Sound human third molars (60 maxillary and 60 mandibular) were randomly assigned into 12 groups (n = 10) according to the type of cavity preparation and the respective buccolingual width. Class II mesio-occlusodistal cavity preparations, for both indirect inlay and direct resin restorations, were prepared with standardized dimensions of one-half, one-third, or one-quarter of the occlusal intercuspal distance. Fracture resistance was lower and weight loss was greater for all nonretentive preparations. Greater losses in weight and fracture resistance occurred when the buccolingual width for both types of cavities increased, except for the weight loss of the one-quarter and one-third indirect cavity preparations in the mandibular molars, and the fracture resistance of the one-half and one-third direct cavity preparations in maxillary molars. Higher tooth structure loss and lower fracture strength were recorded after preparation of the inlay cavities.


Assuntos
Preparo da Cavidade Dentária/métodos , Dente Molar/cirurgia , Fraturas dos Dentes/etiologia , Preparo da Cavidade Dentária/efeitos adversos , Análise do Estresse Dentário , Humanos , Técnicas In Vitro , Dente Molar/patologia , Fraturas dos Dentes/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...